Preparation for Entry Into the Fuel Tank

It is most important to ensure that all persons who are engaged in the process of Fuel Tank Entry are fully trained on all aspects of the following information to ensure that all precautions are taken and all risks minimised.

Steps which must be taken include the following:

a) Ensure the aircraft is electrically grounded

b) Ensure that Fire Extinguishers are available (typically CO2 would be used for a Fuel Fire

c) Deactivate all Electrical Systems on the Aircraft and suitable placard

d) Defuel the aircraft using the Aircraft Maintenance Manual Procedures

e) Deliver a safe atmosphere for maintenance personnel by ensuring the following: